Product Details:
| Power Rating | 5.5 HP |
| Model Name/Number | VFD040ED43S |
| Input Frequency | 47~63 HZ |
| Output Current | 11.5 Amp |
| Start Up Torque | 0.5 Hz / 150% |
Additional Information:
Product Details:
| Power Rating | All Range Available |
| Brand | Delta |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD150ED43S |
| Output Power | 15KW/20HP |
| Input Voltage | 3-phase 380 ~ 480 V,50 / 60 Hz +-10 % (342 ~ 528 V) |
| Input Frequency | 47~63 HZ |
| Output Current | 30 AMP |
Product Details:
| Power Rating | All Range Available |
| Brand | Delta |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD185ED43S |
| Output Power | 18.5KW/25HP |
| Input Voltage | 3-phase 380 ~ 480 V,50 / 60 Hz +-10 % (342 ~ 528 V) |
| Input Frequency | 47~63 |
| Output Current | 38 Amp |
| Start Up Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Control Procedure | 1: V / F,2: VF+PG,3: SVC,4: FOC+PG,5: TQC+PG,6: FOC+PM |
| Ambient Temp. | 10 C~ 40 C,Up to 50 C under derating operation |
| Installation Type | Altitude 1,000 m or lower,keep from corrosive gasses,liquid and dust. |
| Acceleration Time | 0.00 ~ 600.00 seconds |
| Input Tolerance | (342 ~ 528 V) |
| Capacity | 18.5KW/25HP |
| Starting Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
Additional Information:
Product Details:
| Power Rating | All Range Available |
| Brand | Delta |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD220ED43S |
| Output Power | 22KW/30HP |
| Input Voltage | 3-phase 380 ~ 480 V,50 / 60 Hz,+-10 % (342 ~ 528 V) |
| Input Frequency | 47~63 HZ |
| Output Current | 45 Amp |
| Start Up Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Control Procedure | 1: V / F,2: VF+PG,3: SVC,4: FOC+PG,5: TQC+PG,6: FOC+PM |
| Installation Type | 1: V / F,2: VF+PG,3: SVC,4: FOC+PG,5: TQC+PG,6: FOC+PM |
| Acceleration Time | 0.00 ~ 600.00 seconds |
| Input Tolerance | Voltage Tolerance +-10 % (342 ~ 528 V) |
| Capacity | 22KW/30HP |
| Starting Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
Additional Information:
Product Details:
| Power Rating | All Range available |
| Brand | Delta |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD300ED43S |
| Output Power | 30KW/40HP |
| Input Voltage | 3-phase 380 ~ 480 V,50 / 60 Hz +-10 % (342 ~ 528 V) |
| Input Frequency | 47~63 HZ |
| Output Current | 58 Amp |
| Start Up Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Control Procedure | 1: V / F,2: VF+PG,3: SVC,4: FOC+PG,5: TQC+PG,6: FOC+PM |
| Ambient Temp. | -10 C~ 40 C,Up to 50 C under derating operation |
| Input Tolerance | 3-phase 380 ~ 480 V,50 / 60 Hz +-10 % (342 ~ 528 V) |
| Starting Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
Delta Elevator Drive ED Series
Application:Home elevator, cargo elevator, passenger elevator in both residential and commercial buildings
Delta's VFD-ED series AC motor drive designed for elevators are based on years' of experiences in designing AC motor drives, and the experience accumulated since the first Delta elevator AC motor drive VL series launched in 2007. The VFD-ED Series Not only keep safety as first priority but also enhances operation efficiency and riding comfort.
Home elevator, cargo elevator, passenger elevator in both residential and commercial buildings
Additional Information:
Product Details:
| Power Rating | All Range Available |
| Brand | Delta |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD370ED43S |
| Output Power | 37KW/50HP |
| Input Voltage | 3-phase 380 ~ 480 V,50 / 60 Hz,+-10 % (342 ~ 528 V) |
| Input Frequency | 47~63 HZ |
| Output Current | 80Amp |
| Start Up Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Control Procedure | 1: V / F,2: VF+PG,3: SVC,4: FOC+PG,5: TQC+PG,6: FOC+PM |
| Ambient Temp. | -10 C~ 40 C,Up to 50 C under derating operation |
| Installation Type | Altitude 1,000 m or lower,keep from corrosive gasses,liquid and dust. |
| Acceleration Time | 0.00 ~ 600.00 seconds |
| Warranty | 12 Months |
| Input Tolerance | 3-phase 380 ~ 480 V,50 / 60 Hz,+-10 % (342 ~ 528 V) |
| Capacity | 37KW/50HP |
| Starting Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
Additional Information:
Product Details:
| Power Rating | All Range Available |
| Input Phase | Three Phase |
| Brand | Delta |
| Output Power | 45KW/60HP |
| Output Current | 100 Amp |
| Input Frequency | 47~63 HZ |
| Input Voltage | 3-phase 380 ~ 480 V,50 / 60 Hz,+-10 % (342 ~ 528 V) |
| Model Name/Number | VFD450ED43S |
| Start Up Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Frequency | Output Frequency 0.00 to 400 Hz |
| Power | 45KW |
| Installation Type | Altitude 1,000 m or lower,keep from corrosive gasses,liquid and dust. |
| Input Tolerance | 3-phase 380 ~ 480 V,50 / 60 Hz,+-10 % (342 ~ 528 V) |
Product Details:
| Power Rating | All Range Available |
| Brand | Delta |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD550ED43S |
| Output Power | 55KW/75HP |
| Input Voltage | 3-phase 380 ~ 480 V,50 / 60 Hz,+-10 % (342 ~ 528 V) |
| Input Frequency | 47~63HZ |
| Output Current | 128 Amp |
| Start Up Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Control Procedure | 1: V / F,2: VF+PG,3: SVC,4: FOC+PG,5: TQC+PG,6: FOC+PM |
| Ambient Temp. | -10 C~ 40 C,Up to 50 C under derating operation |
| Installation Type | Altitude 1,000 m or lower,keep from corrosive gasses,liquid and dust. |
| Acceleration Time | 0.00 ~ 600.00 seconds |
| Warranty | 12 Months |
| Overload Capacity | Constant torque: 150 % for 60 seconds,variable torque: 180 % for 10 seconds |
| Input Tolerance | 3-phase 380 ~ 480 V,50 / 60 Hz,+-10 % (342 ~ 528 V) |
| Capacity | 55KW/75HP |
Additional Information:
Product Details:
| Power Rating | All Range Available |
| Brand | Delta |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD750ED43S |
| Output Power | 75KW/100 HP |
| Input Voltage | 3-phase 380 ~ 480 V,50 / 60 Hz,+-10 % (342 ~ 528 V) |
| Input Frequency | 47~63 HZ |
| Output Current | 165 Amp |
| Start Up Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Control Procedure | 1: V / F,2: VF+PG,3: SVC,4: FOC+PG,5: TQC+PG,6: FOC+PM |
| Ambient Temp. | -10 C~ 40 C,Up to 50 C under derating operation |
| Installation Type | Altitude 1,000 m or lower,keep from corrosive gasses,liquid and dust. |
| Acceleration Time | 0.00 ~ 600.00 seconds |
| Capacity | 75KW/100 HP |
Additional Information:
Product Details:
| Brand | Delta |
| Output Power | 2.2KW/3HP |
| Input Voltage | Single-phase 200 ~ 240 V 50 / 60Hz,+-10 % (180 ~ 264 V) |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD022ED21S |
| Output Current | 12 Amp |
| Input Frequency | 47~63 HZ |
| Start Up Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Control Procedure | 1: V / F,2: VF+PG,3: SVC,4: FOC+PG,5: TQC+PG,6: FOC+PM |
| Ambient Temp. | -10 C~ 40 C,Up to 50 C under derating operation |
| Installation Type | Altitude 1,000 m or lower,keep from corrosive gasses,liquid and dust. |
| Acceleration Time | 0.00 ~ 600.00 seconds |
| Starting Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
Delta's VFD-ED series AC motor drive designed for elevators are based on years' of experiences in designing AC motor drives, and the experience accumulated since the first Delta elevator AC motor drive VL series launched in 2007. The VFD-ED Series Not only keep safety as first priority but also enhances operation efficiency and riding comfort.
Additional Information:
Product Details:
| Brand | Delta |
| Output Power | 5.5KW/7.5HP |
| Input Voltage | 380 ~ 480 V,50 / 60 Hz 3-phase +-10 % (342 ~ 528 V) |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD055ED43S |
| Output Current | 13 |
| Input Frequency | 47~63 HZ |
Application :Home elevator, cargo elevator, passenger elevator in both residential and commercial buildings
Delta's VFD-ED series AC motor drive designed for elevators are based on years' of experiences in designing AC motor drives, and the experience accumulated since the first Delta elevator AC motor drive VL series launched in 2007. The VFD-ED Series Not only keep safety as first priority but also enhances operation efficiency and riding comfort.
Product Details:
| Brand | Delta |
| Output Power | 7.5KW/10HP |
| Input Voltage | 380 ~ 480 V,50 / 60 Hz,+-10 % (342 ~ 528 V) |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD075ED43S |
| Output Current | 17 Amp |
| Input Frequency | 47~63 HZ |
| Start Up Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Control Procedure | 1: V / F,2: VF+PG,3: SVC,4: FOC+PG,5: TQC+PG,6: FOC+PM |
| Ambient Temp. | -10 C~ 40 C,Up to 50 C under derating operation |
| Capacity | 7.5KW/10HP |
| Acceleration Time | 0~600 Sec |
| Starting Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
| Torque | Reach up to 150 % or above at 0.5 Hz. Under FOC+PG or FOC+PM mode,starting torque can reach 150 % a |
Additional Information:
Product Details:
| Brand | Delta |
| Output Power | 11KW/15HP |
| Input Voltage | 3-p,hase 380 ~ 480 V,50 / 60 Hz +-10 % (342 ~ 528 V) |
| Input Phase | 3 - Phase |
| Model Name/Number | VFD110ED43S |
| Output Current | 23 Amp |
| Input Frequency | 47~63 HZ |
Delta's VFD-ED series AC motor drive designed for elevators are based on years' of experiences in designing AC motor drives, and the experience accumulated since the first Delta elevator AC motor drive VL series launched in 2007. The VFD-ED Series Not only keep safety as first priority but also enhances operation efficiency and riding comfort.