Product Details:
Current | The communications adapter device acts as a gateway from DeviceNet network to MODBUS network. |
Output Voltage | Mounting:DIN rail mount. |
Design | Defined as a DeviceNet Communications Device Profile 12 (0xC). |
Brand | delta |
Input Voltage | No external power needed. Power is supplied via RS-485 that is connected to VFD series. Six pins RJ- |
Support OS | DeviceNet Group2 slave functionality including:Explicit connection,Polled connection |
Additional Information:
Product Details:
Current | The communications adapter device acts as a gateway from DeviceNet network to MODBUS network. |
Output Power | DeviceNet Communication Module (CME-DN01) |
Output Voltage | Defined as a DeviceNet Communications Device Profile 12 (0xC). |
Design | There are 8 I/O addresses used to control the length by setting. The I/O mapping address can be set |
Brand | No external power needed. Power is supplied via RS-485 that is connected to VFD series. Eight pins R |
Model Name/Number | DeviceNet Group2 slave functionality includes:(1)Explicit connection (2)Polled connection |
Input Voltage | Object Model |
Communication: All of Delta’s drives are configured with Modbus communication protocol, and allows for communication between many devices connected to the same network. Communicating outside of the Modbus network with Device Net, Profibus, LonWorks and CANopen can be accommodated by using our optional communication accessories.
CME-DN1 Internal DeviceNet card for VFD-E & VFD-EL
Additional Information:
Product Details:
Model Name/Number | CME-USB01 |
Brand | DELTA |
Depth | Operating Temperature:-10oC to 50oC (non-condensing and not frozen) |
Width | Baud Rate:Supports 4800,9600,19200,38400,57600 bps. |
USB Specification | USB v1.1 |
CME-USB01 Internal USB communication card for VFD-E only
Additional Information:
Product Details:
Usage/Application | Interface:5-PIN open removable connector. Of 5.08mm PIN interval |
Bitmap Formats | Transmission method:CAN |
Capacity | Transmission cable:Shielded twisted pair cable (with 2 power cables) |
Configurable Port Speed | Baud rates:125,250,500 kbps and extendable serial baud rate modes |
Connection Capacity | Network protocol:DeviceNet protocol |
Ethernet/IP and MODBUS TCP Card ; VFD-C, CP
DeviceNet/IP Communication Card
DeviceNet Slave Communication Card
Additional Information:
Product Details:
Model Name/Number | CMM-DN01 |
Brand | Delta |
Depth | Transmission Distance:25m/1Mbps |
Width | Interface:Terminal Block |
Transmission Speed | 500k/250k/125k/100k/50k bps and extendable baud rate mode of 1M |
Transmission Method | Explicit message/ Implicit message |
Number of port | 1 |
CMM-DN01 delta VFD-MS300/MH300 accessories for deviceNet communication
Network Protocol DeviceNet
Features
• Support group 2 ony connection method and cyclic I/O date exchange
• Provides EDS file to identify DeviceNet equipment information
• Supports max. 32 words input and 32 words output of paramete mapping
• Node address and Baud rate can be set in the AC motor drive
Additional Information:
Product Details:
Current | PD-01 communication Module for Profibus DP and VFD series drives |
Output Voltage | Cyclical process data exchange (PZD). |
Design | Parameter accessing: cyclical accessing of parameters (PKW). |
Brand | DELTA |
Input Voltage | PROFIBUS supports the control commands SYNC and FREEZE for data synchronization between master and s |
No. Of Ports | Support the configuration of data structure for data exchange with VFD series Drives |
Communication: All of Delta’s drives are configured with Modbus communication protocol, and allows for communication between many devices connected to the same network. Communicating outside of the Modbus network with Device Net, Profibus, LonWorks and CANopen can be accommodated by using our optional communication accessories.
PD-01 External Profibus Module (VFD-B, VFD-M, VFD-S, VFD-F)
Additional Information: